Description:

The Becker Model VRP-SB-PID is a three mode, proportional-integral-derivative, controller providing pressure control when utilized with a spring & diaphragm actuated control valve or in tandem with a pneumatic positioner. The VRP-SB-PID measures process sensing pressure adjusting the signal to the positioner or actuator to maintain the pressure setpoint. The VRP-SB-PID Controller may be utilized for short pressure control applications such as power plant regulation with setpoints ranging from inches WC to 1300 psig. A feedback module is added to the VRP-SB-CH design allowing the controller to respond in quickly and avoid cycling of the pressure system. The VRP-SB-PID features zero steady state bleed and can take a back-pressure.

Benefits
  • The VRP-SB-PID Sensing Pressure and the Control Spring are combined in the same �CH� combined chamber so that only the �net force� in transmitted to the VRP-SB-PID Pilot Body.
  • VRP-SB-PID Pilot Sensitivity improved to �0.75%.
  • The VRP-SB-PID control spring is totally enclosed and protected from potentially corrosive effects of the atmosphere.
  • The New VRP-SB-PID design provides for substantially reduced number of models available. This makes selection and support of VRP-SB-PID Pilots easier.
  • The New �CH� combined chamber is identical in design for all Becker VRP Pilots. Additionally, new control spring designs provide for wider setpoint range for one spring and greater sensitivity.
  • The increased volume of the VRP-SB-PID combined chamber
Usage:
  • Power Plant Type Pressure Control
  • Two-Stage Pressure Cuts
  • Short System Pressure Control
Range of Product:

Setpoint Range: Inches WC to 1300 psig

Alternate Models:

  • Gap Controller (on-off service)
  • Stainless Steel construction

Action:

  • Direct Acting (Increasing output signal on increasing sensing pressure)
  • Reverse Acting (Decreasing output signal on increasing sensing pressure)
  • Field reversible


Bleed Rates (Consumption)

Steady State Bleed*

<10

Non-Bleed Full-Open/Full Closed

Y

Bleed to Pressure

System (BPS�)

Y

VRP-SB-PID Controller

VRP-SB-PID Technical Specifications

Minimum Deadband

0.2% instrument signal

Independent Linearity

�1.0% positioning range

Resolution

0.2% of setpoint

Control Accuracy

� 0.75% of setpoint

Setpoint Range

25 psig � 1300 psig

(172 kPa � 8966 kPa)

VRP-SB-PID Applications

Pressure Control

Flow Control

Power Plant Type Pressure Control

Power Plant Type Flow Control

Surge Control

Power Plant Type Regulation

Compatible Actuators

RPDA Series (Small Models)

RPDA Series (Large Models)

RPSR Series

LPDA Series (Small Models)

LPDA Series (Large Models)

LPSR Series

LD Series

Instrumentation Options

Bleed to Pressure System BPS�

AB Series Atmospheric Bleed Control

NBV Series No-Bleed Valve

DPS-2 Series Non-Bleed Sensor

PS-2 Series Non-Bleed Sensor

SP Series Setpoint Pump

RSM Series Remote Setpoint Module

Panel Mounting

Stainless Steel Option

VB Series Volume Booster

QEV Series Quick Exhaust Valve

I/P Transducer

SLV Series Signal Lock Valve

Sales Literature
Sales Literature in Spanish
Assembly Manual
Instruction Manual
Selection Tables